illumia®Pro3 LED Characterization System
From high bays to headlights and everything in between, we’ve designed an integrating sphere spectroradiometer for your application. Labsphere’s illumia®Plus2 integrating sphere spectroradiometers offer flexibility to meet your most demanding light measurement requirements.
illumiaPlus2 integrating sphere spectroradiometers are available in sizes from 25 cm to 3 m in both 2π and 4π geometries. Choose from three spectrometer options and application-specific electronic modules that help you maximize efficiency and productivity while maintaining high absolute accuracy and repeatability, no matter the application.
Advanced integrating sphere design allowing lamp “hot swap” to achieve greater efficiency and laboratory throughput. Add-on electronic modules increase functionality and simplify compliance with IES LM-79-19, IES LM-78, and equivalent measurement guidelines.
Operate your system from any device at any location and in multiple languages. Automate calibration routines with built in LM-45 stabilization. Meets LM-79-19 and LM-78 measurement methods and industry standard color calculations.
illumia®Plus2 | |||||||
Sphere Size | 25cm | 50cm | 100cm | 165cm | 195cm | 300cm | |
CDS 2600 Based Systems | |||||||
Typical Lumen Range(lumens) -depends on spectral distribution |
0.001-3400 | 0.002-13800 | 0.01-30000 | 0.02-114000 | 0.04-160000 | 0.09-360000 | |
Wavelength Range(nm) | 350-1050 | 350-1050 | 350-1050 | 350-1050 | 350-1050 | 350-1050 | |
4π System Part Number | AA-40074-025 | AA-40074-050 | AA-40074-100 | AA-40074-165 | AA-40074-195 | AA-40074-300 | |
Max 4π DUT Size (ref. LM-78) |
linear lamps | ~16.7cm | ~33.3cm | ~66.7cm | ~110cm | ~130cm | ~200cm |
Area light source (diameter/diagonal) |
~2.5cm | ~5.0cm | ~10cm | ~16.5cm | ~19.5cm | ~30cm | |
2π System Part Number | AA-40072-050 | AA-40072-100 | AA-40072-165 | AA-40072-195 | |||
Max 2π DUT Size (ref. LM-79) | ~10cm | ~20cm | ~33cm | ~39cm | |||
CDS 3020/3030 Based Systems | |||||||
Typical Lumen Range(lumens)-depends on spectral distribution | 0.004-20800 | 0.009-83000 | 0.02-227000 | 0.03-317000 | 0.07-713250 | ||
Wavelength Range(nm) | CDS-3020 | 350-830 | 350-830 | 350-830 | 350-830 | 350-830 | |
CDS-3030 | 360-1100 | 360-1100 | 360-1100 | 360-1100 | 360-1100 | ||
4π System Part Number | CDS-3020 | AA-40084-050 | AA-40084-100 | AA-40084-165 | AA-40084-195 | AA-40084-300 | |
CDS-3030 | AA-40094-050 | AA-40094-100 | AA-40094-165 | AA-40094-195 | AA-40094-300 | ||
Max 4π DUT Size (ref. LM-78) |
linear lamps | ~33.3cm | ~66.7cm | ~110cm | ~130cm | ~200cm | |
Area light source (diameter/diagonal) |
~5.0cm | ~10cm | ~16.5cm | ~19.5cm | ~30cm | ||
2π System Part Number | CDS-3020 | AA-40082-050 | AA-40082-100 | AA-40082-165 | AA-40082-195 | ||
CDS-3030 | AA-40092-050 | AA-40092-100 | AA-40092-165 | AA-40092-195 | |||
Max 2π DUT Size (ref. LM-79) | ~10cm | ~20cm | ~33cm | ~39cm | |||
CDS 600/610 Based Systems | |||||||
Typical Lumen Range(lumens)-depends on spectral distribution | 0.008-1880 | 0.008-1880 | 0.12-16300 | 0.35-37000 | 0.5-57000 | 1.13-128250 | |
Wavelength Range(nm) | CDS-600 | 350-850 | 350-830 | 350-830 | 350-830 | 350-830 | 350-830 |
CDS-610 | 350-1000 | 350-1000 | 350-1000 | 350-1000 | 350-1000 | 350-1000 | |
4π System Part Number | CDS-600 | AA-40024-025 | AA-40024-050 | AA-40024-100 | AA-40024-165 | AA-40024-195 | AA-40024-300 |
CDS-610 | AA-40034-025 | AA-40034-050 | AA-40034-100 | AA-40034-165 | AA-40034-195 | AA-40034-300 | |
Max 4π DUT Size (ref. LM-78) |
linear lamps | ~16.7cm | ~33.3cm | ~66.7cm | ~110cm | ~130cm | ~200cm |
Area light source (diameter/diagonal) |
~2.5cm | ~5.0cm | ~10cm | ~16.5cm | ~19.5cm | ~30cm | |
2π System Part Number | CDS-600 | AA-40022-050 | AA-40022-100 | AA-40022-165 | AA-40022-195 | ||
CDS-610 | AA-40024-050 | AA-40024-100 | AA-40024-165 | AA-40024-195 | |||
Max 2π DUT Size (ref. LM-79) | ~10cm | ~20cm | ~33cm | ~39cm | |||
Above Systems Include | |||||||
illumia®Plus2 Control Module ICM-500 | |||||||
Integral Software | |||||||
Optional accessories | |||||||
Flicker-iP Flicker Test Accessor(Order Number: AA-01510-000) | |||||||
Spectrally-Calibrated Lamp |
Consumer Electronics
Labsphere is one of the global leaders in light measurement, with over 35 years of experience illustrating our customers advancing light technology. High-end consumer electronics have driven the rapid development of imaging and lighting optics. Labsphere has a suite of products that enhance the design and functionality of your imaging technology at every level, from sensor to product and in between.
Unmanned & Vehicle
Confused about what equipment and processes are required for an automotive lighting and sensor project? With over 35 years in the lighting industry, Labsphere has the expertise to help you. We can illustrate the tools you need to determine the design and compliance of products to global industry and regulatory standards.
Lighting
Light is produced by many natural and artificial light sources. Controlling light and knowing exactly its output, direction, and appearance of the objects it illuminates is the key to light source product development, quality, and success. Here are just a few examples to see Labsphere's state-of-the-art in light measurement.
Other customized products
Using an external testing facility can be expensive and slow down your product development—Labsphere has the solution.
To meet ever-changing product standards, continuous testing at external testing facilities is required. This has led to soaring costs, in addition to severely slowing the time to launch new products and affecting their ability to sell well. Labsphere can assist you in setting up an in-house lab to solve all of these problems quickly and cost-effectively. Contact Isuzu Optical Corp.