Features
- SE2030 spectrometer is composed of CCD sensor and 32bits RISC microcontroller, which has a simplified structure and optimized spectral analysis core. In terms of spectrum measurement, its optical structure can provide very strong and stable measurement performance, especially in terms of resolution and wavelength drift, it has excellent temperature and humidity, vibration, and impact stability. The miniaturized design provides flexibility for various system integration.
Specifications
SE2030 180-1100nm | |
Wavelength Range | 180-1100nm |
Model | SE2030; Czerny-Turner optical structure 2nd order, 3rd order light exclusion |
Sensor | HAMAMATSU S11639快速曝光CMOS |
Dynamic range (the calculation of dynamic range is calculated by the average value of dark noise of multiple spectrometers) | 3500 (Sensor clock performance at 2.5MHz) 3000 (Sensor clock performance at 10MHz) |
SNR | 350 |
Optical System Parameters | Focal Length(R1-R2):60-60 It is recommended that the user design the NA value of the incident light to be greater than the NA value of the spectrometer design |
Physical Dimension | 110(L) x 86(W) x 32.4(H) mm |
Grating | 15 gratings to choose from wavelength selection from UV to NIR |
Slit Width | 10, 25, 50, 100, 200, 300 um |
Integration Time | 0.2ms ~ 65sec, according to the selected sensor type |
Wavelength Accuracy | ± 0.3 nm |
Resolution (Peak FWHM) | From 0.2 nm ~ 10.5 nm, assembled according to different specifications |
Temperature Stability | <0.04nm/°C |
Storage Temperature | -30°C to +70°C |
Operating Temperature | 0°C to +50°C |
Environment Humidity | 0% - 90% non-condensing |
Interface | USB 2.0 @ 480 Mbps (High Speed) |
Spectrometer Fiber Interface | SMA905: Φ3.18±0.005mm SMA905: Φ3.20±0.01mm |
System hole locking recommended torque | 0.3 Nm |
Power Specifications | Power Requirement: 300mA at +5 VDC Support voltage: 4.75-5.25 Boot time: < 4s USB USB Maximum input power supply Vcc: +5.25VDC I/O signal voltage: +5.5VDC |
Optical Measurements
• Reflectance, Transmittance, Absorbance
Biomedical testing
• Measuring Glucose Using Fluorescence
• Determination of protein, triglycerides using UV absorption method
• Measurement of electrolytes, bilirubin using colorimetry
• Measuring Uric Acid Using Enzyme Immunoassay
Photoelectric detection
• LED white light (after packaging) testing equipment
• Solar panel reflectance measurement equipment
• Laser wavelength calibration
• Screen Chromatic Difference Correction
Environmental test
• Air quality
• Water Quality Monitoring