SE2030 180-1100nm

SE2030 180-1100nm
Features
  • SE2030 spectrometer is composed of CCD sensor and 32bits RISC microcontroller, which has a simplified structure and optimized spectral analysis core. In terms of spectrum measurement, its optical structure can provide very strong and stable measurement performance, especially in terms of resolution and wavelength drift, it has excellent temperature and humidity, vibration, and impact stability. The miniaturized design provides flexibility for various system integration.
Specifications
SE2030 180-1100nm
Wavelength Range 180-1100nm
Model SE2030; Czerny-Turner optical structure 2nd order, 3rd order light exclusion
Sensor HAMAMATSU S11639快速曝光CMOS
Dynamic range (the calculation of dynamic range is calculated by the average value of dark noise of multiple spectrometers) 3500 (Sensor clock performance at 2.5MHz)
3000 (Sensor clock performance at 10MHz)
SNR 350
Optical System Parameters Focal Length(R1-R2):60-60 It is recommended that the user design the NA value of the incident light to be greater than the NA value of the spectrometer design
Physical Dimension 110(L) x 86(W) x 32.4(H) mm
Grating 15 gratings to choose from wavelength selection from UV to NIR
Slit Width 10, 25, 50, 100, 200, 300 um
Integration Time 0.2ms ~ 65sec, according to the selected sensor type
Wavelength Accuracy ± 0.3 nm
Resolution (Peak FWHM) From 0.2 nm ~ 10.5 nm, assembled according to different specifications
Temperature Stability <0.04nm/°C
Storage Temperature -30°C to +70°C
Operating Temperature 0°C to +50°C
Environment Humidity 0% - 90% non-condensing
Interface USB 2.0 @ 480 Mbps (High Speed)
Spectrometer Fiber Interface SMA905: Φ3.18±0.005mm
SMA905: Φ3.20±0.01mm
System hole locking recommended torque 0.3 Nm
Power Specifications Power Requirement: 300mA at +5 VDC
Support voltage: 4.75-5.25
Boot time: < 4s USB
USB Maximum input power supply Vcc: +5.25VDC
I/O signal voltage: +5.5VDC

Optical Measurements

• Reflectance, Transmittance, Absorbance

Biomedical testing

• Measuring Glucose Using Fluorescence

• Determination of protein, triglycerides using UV absorption method

• Measurement of electrolytes, bilirubin using colorimetry

• Measuring Uric Acid Using Enzyme Immunoassay

Photoelectric detection

• LED white light (after packaging) testing equipment

• Solar panel reflectance measurement equipment

• Laser wavelength calibration

• Screen Chromatic Difference Correction

Environmental test

• Air quality

• Water Quality Monitoring